This is an outdated version published on 2024-07-07. Read the most recent version.
Preprint has been submitted for publication in journal
Preprint / Version 1

The Reliability and Validity of Different Methods for Measuring Countermovement Jump Height

##article.authors##

DOI:

https://doi.org/10.51224/SRXIV.430

Keywords:

jumping, ForceDecks, OptoJump, Just Jump System, MyJump

Abstract

Previous research indicates the importance of the countermovement jump (CMJ) test to monitor lower-limb power and neuromuscular fatigue. While jump height (JH) can be measured using various equipment, this study compared the JH obtained from the Just Jump System (JJS), OptoJump and the MyJump2 app against the Vald ForceDecks system using the impulse-momentum calculation method, which is regarded as the gold standard method to calculate JH. This study also assessed the one-week test-retest reliability of these pieces of equipment. The participants in this study were 20 (n = 12 male and n = 8 female) university sports students and staff (mean ± SD; age: 20.90 ± 2.63 years; stature: 1.76 ± 0.10 m; mass: 72.17 ± 11.07 kg). Participants completed a standardised warm-up and rested for three minutes before completing three CMJs on each piece of equipment in a randomised, counterbalanced order. The same protocols were used in the second session, with a different equipment testing order. Both MyJump and OptoJump have high agreement levels (Mean bias and 95% CI = 2.32 cm [1.57 – 3.09] and 1.92 cm [1.23 – 2.59], respectively) with the gold measurement standard (ForceDecks using IM). However, a high mean bias for the JJS (Mean bias = 9.88 cm [9.26 – 10.46]) was reported. Overall, the equipment investigated in this study showed high levels of reliability, and only the JJS had low validity compared to the ForceDecks. Coaches should consider what data they want to collect, its validity and reliability, the purpose of the testing and the cost of the equipment when deciding which system to purchase.

Metrics

Metrics Loading ...

References

Akyildiz, Z, Ocak, Y, Clemente, FM, et al. Monitoring the post-match neuromuscular fatigue of young Turkish football players. Scientific reports 12: 13835, 2022.

Allaire, J, Dervieux, C, McPherson, J, et al. rmarkdown: Dynamic documents for R [Manual]. 2024.

Amrhein, V, Trafimow, D, Greenland, S. Inferential statistics as descriptive statistics: There is no replication crisis if we don’t expect replication. The American Statistician 73: 262-270, 2019.

Asmussen, E, Bonde‐Petersen, F. Storage of elastic energy in skeletal muscles in man. Acta physiologica scandinavica 91: 385-392, 1974.

Attia, A, Dhahbi, W, Chaouachi, A, et al. Measurement errors when estimating the vertical jump height with flight time using photocell devices: the example of Optojump. Biology of sport 34: 63-70, 2017.

Bogataj, Š, Pajek, M, Andrašić, S, et al. Concurrent validity and reliability of my jump 2 app for measuring vertical jump height in recreationally active adults. Applied Sciences 10: 3805, 2020.

Chiu, LZ, Dæhlin, TE. Comparing numerical methods to estimate vertical jump height using a force platform. Measurement in Physical Education and Exercise Science 24: 25-32, 2020.

Claudino, JG, Cronin, J, Mezêncio, B, et al. The countermovement jump to monitor neuromuscular status: A meta-analysis. Journal of Science and Medicine in Sport 20: 397-402, 2017.

Collings, TJ, Lima, YL, Dutaillis, B, et al. Concurrent validity and test–retest reliability of VALD ForceDecks' strength, balance, and movement assessment tests. Journal of Science and Medicine in Sport, 2024.

Comyns, TM, Murphy, J, O'Leary, D. Reliability, usefulness, and validity of field-based vertical jump measuring devices. The Journal of Strength & Conditioning Research 37: 1594-1599, 2023.

Dobbin, N, Hunwicks, R, Highton, J, et al. Validity of a jump mat for assessing countermovement jump performance in elite rugby players. International journal of sports medicine 38: 99-104, 2017.

Douglas Bates, M, Bolker, B, Walker, S. Fitting linear mixed-effects models using lme4. Journal of Statistical Software 67: 1-48, 2015.

García-López, J, Morante, JC, Ogueta-Alday, A, et al. The type of mat (contact vs. photocell) affects vertical jump height estimated from flight time. The Journal of Strength & Conditioning Research 27: 1162-1167, 2013.

Gathercole, R, Sporer, B, Stellingwerff, T, et al. Alternative countermovement-jump analysis to quantify acute neuromuscular fatigue. International journal of sports physiology and performance 10: 84-92, 2015.

Gençoğlu, C, Ulupınar, S, Özbay, S, et al. Validity and reliability of “My Jump app” to assess vertical jump performance: a meta-analytic review. Scientific reports 13: 20137, 2023.

Glatthorn, JF, Gouge, S, Nussbaumer, S, et al. Validity and reliability of Optojump photoelectric cells for estimating vertical jump height. The Journal of Strength & Conditioning Research 25: 556-560, 2011.

Heredia-Jimenez, J, Orantes-Gonzalez, E. Comparison of three different measurement systems to assess the vertical jump height. Revista Brasileira de Medicina do Esporte 26: 143-146, 2020.

Hughes, S, Chapman, DW, Haff, GG, et al. The use of a functional test battery as a non-invasive method of fatigue assessment. PloS one 14: e0212870, 2019.

Lakens, D. Sample size justification. Collabra: psychology 8: 33267, 2022.

Landau, WM. tarchetypes: Archetypes for targets [Manual]. 2021.

Landau, WM. The targets R package: A dynamic Make-like function-oriented pipeline toolkit for reproducibility and high-performance computing. Journal of Open Source Software 6: 2959, 2021.

Linthorne, NP. Analysis of standing vertical jumps using a force platform. American Journal of Physics 69: 1198–1204, 2001.

Lombard, W, Reid, S, Pearson, K, et al. Reliability of metrics associated with a counter-movement jump performed on a force plate. Measurement in Physical Education and Exercise Science 21: 235-243, 2017.

Loy, A, Steele, S, Korobova, J. lmeresampler: Bootstrap methods for nested linear mixed-effects models [Manual]. 2024.

McMahon, JJ, Jones, PA, Comfort, P. A correction equation for jump height measured using the just jump system. International journal of sports physiology and performance 11: 555-557, 2016.

Merrigan, JJ, Strang, A, Eckerle, J, et al. Countermovement jump force-time curve analyses: reliability and comparability across force plate systems. The Journal of Strength & Conditioning Research 38: 30-37, 2024.

Nuzzo, JL, Anning, JH, Scharfenberg, JM. The reliability of three devices used for measuring vertical jump height. The Journal of Strength & Conditioning Research 25: 2580-2590, 2011.

Nuzzo, JL, McBride, JM, Cormie, P, et al. Relationship between countermovement jump performance and multijoint isometric and dynamic tests of strength. The Journal of Strength & Conditioning Research 22: 699-707, 2008.

Parker, RA, Scott, C, Inácio, V, et al. Using multiple agreement methods for continuous repeated measures data: a tutorial for practitioners. BMC Medical Research Methodology 20: 1-14, 2020.

Pedersen, TL. patchwork: The composer of plots [Manual]. 2024.

Pino-Ortega, J, Rojas-Valverde, D, Gómez-Carmona, CD, et al. Training design, performance analysis, and talent identification—A systematic review about the most relevant variables through the principal component analysis in Soccer, Basketball, and Rugby. International journal of environmental research and public health 18: 2642, 2021.

Pueo, B, Penichet-Tomas, A, Jimenez-Olmedo, J. Reliability and validity of the Chronojump open-source jump mat system. Biology of sport 37: 255-259, 2020.

Rago, V, Brito, J, Figueiredo, P, et al. Countermovement jump analysis using different portable devices: Implications for field testing. Sports 6: 91, 2018.

Şentürk, D, Yüksel, O, Akyildiz, Z. The concurrent validity and reliability of the My Jump Lab smartphone app for the real-time measurement of vertical jump performance. Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology: 17543371241246439, 2024.

Team, RC. R: A language and environment for statistical computing [Manual]. R Foundation for Statistical Computing. 2024.

Ushey, K, Wickham, H. renv: Project environments [Manual]. 2023.

Whitmer, TD, Fry, AC, Forsythe, CM, et al. Accuracy of a vertical jump contact mat for determining jump height and flight time. The Journal of Strength & Conditioning Research 29: 877-881, 2015.

Wickham, H, Averick, M, Bryan, J, et al. Welcome to the tidyverse: Journal of Open Source Software, v. 4. doi 10: 1686, 2019.

Wisløff, U, Castagna, C, Helgerud, J, et al. Strong correlation of maximal squat strength with sprint performance and vertical jump height in elite soccer players. British journal of sports medicine 38: 285-288, 2004.

Xie, Y. A comprehensive tool for reproducible research in R, in: Implementing reproducible computational research. V Stodden, F Leisch, RD Peng, eds.: Chapman and Hall/CRC., 2014.

Xie, Y. Dynamic documents with R and knitr Chapman and Hall/CRC, 2015.

Xie, Y. knitr: A general-purpose package for dynamic report generation in R [Manual]. 2024.

Xie, Y, Allaire, JJ, Grolemund, G. R markdown: The definitive guide. Chapman and Hall/CRC., 2018.

Xie, Y, Dervieux, C, Riederer, E. R markdown cookbook. Chapman and Hall/CRC., 2020.

Xu, J, Turner, A, Comfort, P, et al. A systematic review of the different calculation methods for measuring jump height during the countermovement and drop jump tests. Sports Medicine 53: 1055-1072, 2023.

Yingling, VR, Castro, DA, Duong, JT, et al. The reliability of vertical jump tests between the Vertec and My Jump phone application. PeerJ 6: e4669, 2018.

Posted

2024-07-07

Versions